TXE2 - D Switch
Circuit Diagram Notes
Circuit Diagram Notes
Test and Mark Relay
Test and Mark Relay
Relay SB is normally operated.
When a connection is to be established between a seized Incoming or Own-exchange Supervisory Relay Set and a Subscriber's Line Circuit, that Supervisory Relay Set applies negative battery to its A-lead, operating access relays TA-TD.
Operation of the access relays allows the C-Switch Selector to determine which links are free, and to select and mark one of them. (Free links have a positive potential on the H wire; engaged links a negative potential.)Â
The 'mark' is a +22 V zener potential applied, via the C-Switch Selector, from the B-Switch Selector and operates the crosspoint relay which is common to the Supervisory Relay-Set and chosen C-D link.
Power Connections
Power Connections
Alarm Relay
Alarm Relay
TXE2 PDFs below....
TXE2 PDFs below....
TXe2_D switch_Diagram_Notes_AT_71610_1_clean.pdf
AT________71610____1_3.pdf
Sheet 2 of Schematic below
Sheet 2 of Schematic below
AT________71610____2__clean.pdf
AT_______703401S________2__2B.pdf